Improving the On-Line Extraction of Polar Compounds by IT-SPME with Silica Nanoparticles Modified Phases

2018

In the present work the extraction efficiency of in-tube solid-phase microextraction (IT-SPME) for polar herbicides has been evaluated using extractive capillaries coated with different polymeric sorbents. For this purpose, aqueous solutions of herbicides with a wide range of polarities, including some highly polar compounds (log Kow < 1), have been directly processed by IT-SPME coupled on-line to capillary liquid chromatography with UV-diode array detection. For extraction, commercially available capillary columns coated with polydimethylsiloxane (PDMS) and polyetilenglicol (PEG)-based phases have been used, and the results have been compared with those obtained with a synthesized tetra…

Materials scienceCapillary actionin-tube solid-phase microextraction (IT-SPME); polar herbicides; capillary liquid chromatography; SiO<sub>2</sub> nanoparticlesFiltration and Separationengineering.material010402 general chemistry01 natural sciencesAnalytical Chemistrylcsh:Chemistrychemistry.chemical_compoundCoatingchemistry.chemical_classificationDetection limitAqueous solutionChromatographyPolydimethylsiloxane010401 analytical chemistryExtraction (chemistry)Polymercapillary liquid chromatographySiO2 nanoparticleslcsh:QC1-9990104 chemical sciencesTetraethyl orthosilicatechemistrylcsh:QD1-999engineeringpolar herbicideslcsh:Physicsin-tube solid-phase microextraction (IT-SPME)Separations
researchProduct

On-line in-tube solid phase microextraction coupled to capillary liquid chromatography-diode array detection for the analysis of caffeine and its met…

2019

Abstract In-tube solid phase microextraction (IT-SPME) coupled on-line to capillary liquid chromatography with diode array detection provides a simple and fast analytical methodology for the simultaneous quantitation of caffeine and its three primary metabolites (theobromine, paraxanthine and theophylline) in micro samples of serum, saliva and urine matrices. The sample amount required for one analysis was only 2.5 μL of saliva, 6.25 μL of serum or 40 μL of urine, a requirement for its implementation in a hospital laboratory for preterm newborns, where sample availability is a major problem. In standard conditions, 25 μL of diluted saliva or serum (or 100 μL of urine) were processed by IT-S…

SalivaAnalyteClinical BiochemistryPharmaceutical ScienceUrineUrineSolid-phase microextraction01 natural sciencesAnalytical Chemistrychemistry.chemical_compoundTheophyllineCaffeineDrug DiscoverymedicineHumansSalivaTheobromineSolid Phase MicroextractionSpectroscopyParaxanthineDetection limitChromatography010405 organic chemistryElution010401 analytical chemistry0104 chemical scienceschemistryCalibrationTheobromineBiological samples Capillary liquid chromatography In-tube solid-phase microextraction TrimethylxanthinesChromatography Liquidmedicine.drug